TR TR
Stinga Enerji A.Ş.
Home › In the Press › Marmara'nın Bypass Crisis in Numbers: 100,000 Per Day...
13 August 2026 Energy Technology

Marmara's Bypass Crisis in Figures: 100,000 Cubic Meters of Sewage per Day

The numerical scale of the Ambarlı case shows that the problem is not an isolated malfunction, but a structural capacity shortfall. Three penalties in 15 months, 70% annual increase, and 4 different discharge points — decision-support analysis with data.

Marmara's Bypass Crisis in Figures: 100,000 Cubic Meters of Sewage per Day
DATA ANALYSIS

The administrative fine of 8.39 million TL imposed on İSKİ by the Ministry of Environment on 12 August 2026 was the third sanction in just the past year. The figures show that the Ambarlı case is not an isolated operational error; it is the natural result of a hydraulic capacity crisis.

400.000m³/day
plant capacity
100.000m³/day
bypass flow rate
%25bypass ratio
(estimated)
8.391.988TL
current fine

Chronology and Trend Analysis of the Fines

Although only 15 months passed between the three penalties issued to the Ambarlı facility, the penalty amount increased by more than twofold. This indicates that the deterrent effect of penalties is weaker than their effect on eliminating the problem.

26 May 2025
First Fine — 3,343,000 TL
The Ministry identified parameter exceedances in the facility's effluent. The penalty remained relatively low compared to İSKİ's operational budget.
16 January 2026
Second Fine — 6,687,000 TL
As the problem recurred, the penalty was increased by approximately twofold. The Ministry recorded the capacity shortfall for the first time in its report.
12 August 2026
Third Fine — 8,391,988 TL
An untreated discharge of 100,000 m³ per day was detected from the bypass line. A lack of flow meters was identified at four separate discharge points.

One-year increase rate: 151%. Even if the penalties multiply, as long as the facility's physical capacity does not change, the data confirm that sanctions do not alter behavior.

What does 100,000 cubic meters mean?

100,000 cubic meters of wastewater per day means the equivalent of 6,666 vacuum trucks with a standard capacity of 15 cubic meters being discharged into the Marmara Sea. On an annual basis, this figure reaches 36.5 million cubic meters — a volume roughly equal to about 10% of a medium-sized dam reservoir.

36.5 million m³ of untreated wastewater per year — this is equivalent to approximately 40% of the water volume of Küçükçekmece Lake. It is discharged directly into the receiving environment.

Source of the problem: Hydraulic load and sludge accumulation

Conventional advanced biological treatment plants either lose treatment efficiency or bring the bypass line into operation once the hydraulic load exceeds nominal capacity. The bypass ratio at the Ambarlı facility being at 25% indicates that capacity must be expanded by at least 30%.

The time required to carry out this expansion using the conventional method is 24–36 months. Over this period, the penalty amount — with the 70% annual increase trend — may exceed the facility's initial investment cost. Modular and carbonizing drying-based additional units can be put into operation within 6–9 months.

Technical Evaluation

Hydraulic Load Management with Carbonized Drying

The reactor-top carbonizing drying system developed by Stinga Enerji enables the wet sludge generated at the final stage of the wastewater treatment process to be carbonized in an oxygen-free environment. This produces two simultaneous outcomes:

ParameterConventional DisposalCarbonized Drying
Sludge volume (after input)100%10–20%
Moisture content%75–80Under 5%
Disposal energy requirementAdditional fuel requiredAutocatalysis (net energy generation)
Output productStorage wasteAlternative fuel for cement plants
EmissionsCO, NOx, VOC riskNear-zero volatile emissions (oxygen-free)
Installation time24–36 months6–9 months (modular)

Source: Stinga Enerji A.Ş. R&D data; measurement reports from TÜBİTAK and ENKA Laboratory.

Increasing penalties does not solve the problem.
Expanding capacity does.
Data sources: Ministry of Environment, Urbanization and Climate Change statement (12 August 2026) · Milliyet Uzman Para — Go to article. Comparative data: Stinga Enerji R&D Directorate.
All News
01 / 01
⬇
AI
Our Services
Industrial Machine
Activated Carbon
Mining
Coal Drying
Wood Chips Drying
Bentonite Drying
Sewage Sludge Disposal
Poultry
Residential Heating