TR TR
Stinga Enerji A.Ş.

Residential Heating Systems

Stinga Enerji A.Ş. Residential-Type Reactor Domestic & National · Patent in 134 Countries
SOLID FUEL
REACTOR
BOILER SYSTEM
Residential-Type Central Heating & Hot Water Production
Developed with Stinga's patented zero-emission combustion technology, this system heats 100 independent apartments from a single center and can produce continuous hot water. By burning coal with at least 4.500 Kcal/kg calorific value, it delivers 97.5% NCV combustion efficiency. Fully autonomous operation with automatic coal feeding and ash discharge system.
// Technical Summary
FUEL QUALITY≥ 4,500 Kcal/kg
CAPACITY100 INDEPENDENT APARTMENTS
COMBUSTION EFFICIENCY97.5% NCV
HOT WATER OUTLET80 °C
FLUE GAS OUTLET23 °C / OPEN TO AMBIENT
SO₂3 ppm
CO48 mg/m³
Stinga Reactor
100 Circle
Heating Capacity
Single system, central distribution
97,5%
Combustion Efficiency (NCV)
Accredited laboratory measurement
80°C
Hot Water Outlet Temperature
Continuous uninterrupted production
23°C
Stack Gas Outlet Temperature
Open to ambient — safe
01
Emission & Efficiency Values
The Stinga Residential-Type Reactor Boiler has been tested with the boiler room open to the parking area and without any stack system. Flue gas is released directly into the environment at 23°C, providing an output clean enough not to affect human health. While conventional coal boilers have SO₂ values in the 400–1.500 ppm range, Stinga produces only 3 ppm.
Measurement Date
12.09.2011
Test Condition
OPEN TO ATMOSPHERE
💨
SO₂ Value
3 ppm
While the EU limit is 200 mg/m³, Stinga operates well below this limit.
🔬
CO Value
48 mg/m³
Despite the WHO guideline limit of 10,000 µg/m³, it operates within a very safe range.
⚡
Combustion Efficiency (NCV)
%97,5 ✓
While standard coal boilers provide 75–82% NCV, Stinga sets an industry record with 97.5%.
🌡️
Flue Gas Temperature
57,6 °C
While traditional boilers have an outlet of 200–350°C, Stinga reduces it to 57.6°C.
🌬️
NO / NOₓ Value
74/119 mg/m³
Nitrogen oxide values remain far below industrial standard limits.
💧
Excess Air Ratio
1,27
Complete combustion is achieved with the optimum excess air ratio.
// Accredited Laboratory Measurement · 12.09.2011
STINGA EMISSIONS
LOWER THAN NATURAL GAS TOO
A coal-fired system produces flue gas cleaner than even natural gas boilers
400–1.500
Coal SO₂ (ppm)
~15
Natural Gas SO₂ (ppm)
3
Stinga SO₂ (ppm)
By operating with COAL — natural gas's 5X CLEANER produces flue gas
02
Cost Calculation Detail
The system consumes 15 kg per hour by burning 0–10 mm dust coal (6.000 Kcal/kg). It is based on 6 hours per day and 7 months per year of operation. Electricity 5.5 kW/hour / 3.24 TL/kWh, exchange rate 1 USD = 45 TL, natural gas reference 100 m² residence annual 22.000 TL, personnel 1.200 USD/month.
Coal Price
120 USD/TON
Electricity Price
3.24 TL/kWh
Exchange Rate
1 USD = 45 TL
Staff
1.200 USD/MONTH
Hourly Coal
15 kg/hour
0–10 mm powdered coal, 6,000 Kcal/kg
15 kg Coal Cost
$1,80 /hour
120 USD/ton × 15 kg ÷ 1,000
Daily Fuel (6 Hours)
$10,80 /day
1.80 USD × 6 hours
Monthly Fuel
$324 /month
10.80 USD × 30 days
7-Month Fuel
$2.268 /year
324 USD × 7 months
Annual Coal
18,9 ton/year
15 kg × 6h × 30g × 7 months = 18,900 kg
Hourly Electricity
5,5 kW/h
Total system power consumption
Daily Electricity
33 kWh
5,5 kW × 6 hours
Annual Electricity
6.930 kWh
33 kWh × 30g × 7months
Electricity (TL)
22.453 TL
6,930 × 3,24 TL
Electricity (USD)
$499 /year
22,453 TL ÷ 45
Fuel + Electricity
$2.767 /year
$2.268 + $499
Monthly Personnel
$1.200 /month
1 full-time staff
Annual Personnel
$14.400 /year
1.200 × 12 months
Grand Total
$17.167 /year
Fuel + Electricity + Personnel
// Residential Heating & Hot Water — Cost per Apartment
MONTHLY PER APARTMENT
$14,31
USD / month
≈ 644 TL / month
Calculated on a 12-month basis.
Includes residential heating + hot water.
ANNUAL PER APARTMENT
$171,67
USD / year
≈ 7,725 TL / year
$17.167 total ÷ 100 apartments
Fuel + Electricity + Personnel
SAVINGS COMPARED TO NATURAL GAS
$317,22
USD / apartment / year
≈ 14,275 TL / year
$488,89 − $171,67
= $317.22 annual savings
Calculation: Fuel $2.268 + Electricity $499 + Personnel $14.400 = $17.167/year → Annual per apartment: $17.167 ÷ 100 = $171,67 → Monthly per apartment: $171,67 ÷ 12 = $14,31/month → Savings: $488,89 − $171,67 = $317,22/apartment/year
03
Annual Cost Comparison
Annual heating cost of 100 apartments. Stinga values are based on R&D calculations: 15 kg/hour dust coal, 6 hours/day, 7 months/year, 120 USD/ton, 3.24 TL/kWh, 1 USD=45 TL, 1 personnel 1.200 USD/month. Natural gas reference 22.000 TL/apartment/year (488,89 USD).
Base Year
2026 USD
Reference Unit
100 APARTMENTS / YEAR
LOWEST COST
Stinga KTR-100D
SOLID FUEL REACTOR BOILER
$17.167 /year
FUEL (annual)$2.268
ELECTRICITY (annual)$499
STAFF (annual)$14.400
EFFICIENCY97.5% NCV
STACK SYSTEMUNNECESSARY
ANNUAL PER APARTMENT$171,67
MONTHLY PER APARTMENT$14,31
HIGHEST COST
Traditional Coal
CONVENTIONAL — 35% EFFICIENCY
$57.600 /year
EFFICIENCY35% NCV
CO EMISSION100–500 ppm
SO₂ EMISSION400–1.500 ppm
EMISSION PENALTYHIGH RISK
ANNUAL PER APARTMENT$576
MONTHLY PER APARTMENT$48
CRITERIONSTİNGA KTR-100DCENTRAL NATURAL GASTRADITIONAL COAL
Total Annual (100 Apartments)$17.167$48.889$57.600
Annual Fuel Cost$2.268$48.889~$53.500
Annual Electricity$499Included in the invoice~$1.000
Staff (Annual)$14.400—~$6.000
Savings Compared to Natural Gas$31.722/year— Reference$8,711 more expensive
10-Year Cumulative Savings$317.220— ReferenceMore expensive than natural gas
Stack System$0 — Not Required$8–15k USD$5–12k USD
Annual Per Apartment$171,67$488,89$576
Monthly Per Apartment$14,31$40,74$48
Combustion Efficiency97.5% Record%90–9435% Low
SO₂ Emission3 ppm~15 ppm400–1.500 ppm
CO Emission48 mg/m³~75 mg/m³100–500 ppm
Exchange RiskNone — Domesticly developedHigh — ImportedLow — Domesticly developed
Emission Penalty RiskMinimumLowVery High
04
System Components
Reactor Boiler
// Boiler Body

Reactor Body Consisting of 3 Parts
Stinga Reactor Boiler is manufactured in three separate parts. The modular structure can be easily installed even in confined spaces. Not needing a stack system eliminates the additional $8.000–15.000 USD cost.
REACTOR BODY3-Piece Modular
COMBUSTION WINDOWFlame Observation
CONTROL PANELIncluded
INSTALLATION TIME2–3 Business Days
ADDITIONAL INFRASTRUCTURENot Required
⚙️
Proportional Coal Dispensing Motor
Feeds coal into the reactor proportionally and in a controlled manner. Combustion speed is automatically adjusted according to demand.
🏗️
Coal Feeding Bunker
The yellow feed hopper stores the coal and delivers it downward. It is conveyed continuously to the reactor with a screw system.
🌀
Automatic Ash Discharge
The screw beneath the boiler automatically carries the combustion residue ash बाहर. It is an indicator of 97.5% efficiency.
💧
Cold Water Inlet & Hot Water Outlet
Mains water is heated to 80°C and supplied to the building distribution system. Heating and hot water at the same time.
🔌
Control & Automation Panel
Electronic panel that monitors all system parameters. Coal feed rate, temperature, and safety alarms.
💨
Flue Gas Extraction Fan
After 97.5% NCV combustion, flue gas can be safely released to the environment at 23°C. No external stack is required.
05
Technical Specifications
Emission Values
// Flue Gas System
Clean Flue Gas
Outlet Technology
The boiler has been tested in a parking lot environment without a stack system. The exhaust is clean enough to be released into an enclosed space. The $5.000–15.000 USD stack cost is completely eliminated.
SO₂3 ppm
CO48 mg/m³
NOₓ119 mg/m³
FLUE GAS TEMPERATURE INSIDE STACK57,6 °C
AMBIENT OUTLET TEMPERATURE23 °C
EFFICIENCY NCV%97,5
PARAMETERTECHNICAL VALUEEXPLANATION
System TypeSolid Fuel ReactorCentral heating + hot water
Fuel Type0–10 mm Coal Dust6.000 Kcal/kg
Hourly Consumption15 kg/hourProportional feed motor
Heating Capacity100 ApartmentsSingle central system
Hot Water Outlet80 °C — ContinuousContinuous production
Stack Gas Outlet23 °C — Open to EnvironmentIndustry avg. 200–350°C
Combustion Efficiency97.5% — RecordConventional coal 35%
SO₂ Emission3 ppmConventional: 400–1,500 ppm
CO Emission48 mg/m³Well below the WHO limit
NOₓ Emission119 mg/m³EU limit 500 mg/m³
Stack Internal Temperature57,6 °CHigh heat recovery
Boiler Body3-Piece Modular2–3 days installation
Operating ModeAutonomous 24/7Energy savings with sleep mode
Stack SystemNot Required$5–15k USD cost is eliminated
Patent Coverage134 CountriesIncluding Türkiye, the EU, the USA, and China
06
Environmental Impact & Carbon Savings
Stinga KTR-100D's 97.5% combustion efficiency means 20–25% less CO₂ per unit of fuel compared with traditional coal boilers. On a 100-apartment basis, an annual approximately 18–22 ton reduction in CO₂ is achieved.
CO₂ Savings
18–22 Tons/Year
Carbon Value
$900–1,760/YEAR
Annual Coal
18,9 ton
With 97.5% efficiency, 20% less fuel for the same heat.
SO₂ Reduction
97 %
97% reduction compared with conventional boilers.
Natural Gas Savings
$31,7K /year
$317K USD cumulative savings in 10 years.
Energy Independence
%100 domestically developed
Eliminates exchange rate risk with domestic coal.
07
System Advantages
🔥
97.5% NCV Combustion Efficiency
While the sector average is 75–82% NCV, Stinga provides annual savings of $31.722 USD with this difference. Including personnel, the cost per apartment is only $171,67 USD/year.
🌿
Safely Ventilated Flue Gas Open to the Environment
Flue gas can be safely released to the environment at 23°C. Not needing a stack system eliminates an additional $5.000–15.000 USD investment.
⚙️
Full Automation — 24/7
Thanks to proportional coal feeding and automatic ash discharge, the system operates with minimal intervention.
🏗️
Modular 3-Piece Body
Installation is made easier in confined spaces. Installation time is 2–3 business days.
⛏️
Domestic Coal — No Exchange Rate Risk
0–10 mm dust coal at a price of 120 USD/ton. Dependence on imported natural gas is reduced to zero.
🇹🇷
Registered Patent in 134 Countries
Designed entirely with Turkish engineering infrastructure, the system is internationally secured with patent registration in 134 countries.
08
Photo Gallery
Full System
GAL-01 // COMPLETE SYSTEM
Front View
GAL-02 // FRONT VIEW
Boiler Body
GAL-03 // BOILER BODY
Distribution Motor
GAL-04 // DISTRIBUTION MOTOR
Emission Values
GAL-05 // EMISSION MEASUREMENT
STINGA ENERJİ A.Ş. // RESIDENTIAL-TYPE REACTOR-BOILER SYSTEM SYS:STINGA-KTR-100D · 97.5% NCV · PATENT IN 134 COUNTRIES
✕ CLOSE
◀ PREVIOUS
NEXT ▶
Audio Reading
0:00 --:--
Speed:
01 / 01
⬇
AI
Our Services
Industrial Machine
Activated Carbon
Mining
Coal Drying
Wood Chips Drying
Bentonite Drying
Sewage Sludge Disposal
Poultry
Residential Heating