TR TR
Stinga Enerji A.Ş.

Stinga — Double-Deck Drying System

HIGHEST CAPACITY10,000 KG / HOUR

A flagship drying system designed for large-scale municipal treatment plants, delivering maximum efficiency with a double-deck architecture.

10.000kg/hour capacity
%75inlet moisture
%1-5outlet moisture
≈0emission
240 kgfuel/hour
Capacity range: 8,500 – 11,500 kg/h

Technical Data

Technical Specifications

Processing Capacity
10,000 kg / Hour (±15%)
Inlet Moisture Content
~%75
Outlet Moisture Content
%1 – %5
Fuel Consumption
240 kg/hour (6,000 kcal coal)
Design
Double-Deck Drying Architecture
Volume Reduction
> %90
Environmental Compatibility
EU Standards, SKHKKY, Kyoto Protocol
Energy Model
Autocritical — runs on its own biofuel
Hourly Fuel Cost
₺768
240 kg coal × ₺3,200/ton
Disposal Cost per Ton
₺77
Including fuel cost, ton/wet sludge
Coal Price (reference)
$80
6,000 kcal/kg · USD/TRY: ~40 (Sep.2024 reference)

Featured Features

Why Double-Deck?

⚡

Double Efficiency, Same Area

The double-deck architecture offers twice the capacity compared to single-deck systems in the same facility area.

🏭

For Large Municipal Facilities

It meets the daily tonnage sludge needs of ASKİ, İSKİ, and large industrial zones with a single system.

🔄

Autocritical Energy Cycle

The produced biofuel powers the system; dependence on external energy ends after the first ignition.

🌬️

Near-Zero Emissions

Operates far below EU emission limits with multi-stage filtration.

📊

90%+ Volume Reduction

The volume of heavy wet sludge is reduced by over 90%, and the ash is compact and stable.

🛡️

134 Country Patent

Stinga technology is registered in 134 countries — industrial assurance and legal durability.

Media Gallery

Photo & Video

LET'S CALCULATE THE MAXIMUM CAPACITY FOR YOU

We prepare a custom feasibility report based on your facility's daily sludge production amount.

Stinga Ø3400 — Single-Deck Drying System

SINGLE-DECK SYSTEM.5,000 KG/HOUR.

A high-capacity single-deck sludge disposal system in which the reactor and rotary kiln operate as a single system.

5.000kg/hour capacity
%75inlet moisture
%1-5outlet moisture
SINGLE-DECKsingle drum
150 kgfuel/hour
Capacity range: 4,250 – 5,750 kg/h

Technical Data

Technical Specifications

Processing Capacity
5,000 kg / Hour (±15%)
Inlet Moisture Content
~%75
Outlet Moisture Content
%1 – %5
Fuel Consumption
150 kg/hour (6,000 kcal coal)
Installation
Single-deck drum — compact layout
Volume Reduction
> %90
Flexibility
Sewage sludge, coal, and biomass
Energy Model
Autocritical — runs on its own biofuel
Hourly Fuel Cost
₺480
150 kg coal × ₺3,200/ton
Disposal Cost per Ton
₺96
Including fuel cost, ton/wet sludge
Coal Price (reference)
$80
6,000 kcal/kg · USD/TRY: ~40 (Sep.2024 reference)

Featured Features

The Power of the Single-Deck System

🏭

Single System

The reactor and rotary kiln operate as a single system.

⚡

Rapid Commissioning

It is installed on-site and starts operation with minimum preparation time.

💰

Investment Optimization

One system for multiple facilities — spreads capital cost.

🔄

Autocritical Energy

Operates with the biofuel it produces, with no external dependency.

📊

High Capacity

With 5,000 kg/h, it meets the needs of large and medium-sized facilities.

🌿

Environmentally Friendly

Advanced filter system that meets EU emission standards.

Media Gallery

Photo & Video

PLAN THE SINGLE-DECK SYSTEM YOUR WAY

Determine how many facilities you will serve and how often — let us prepare a custom usage plan for you.

Stinga Ø3400 — Reactor-Top Drying System

HIGH CAPACITY.COMPACT STRUCTURE. 3,500 KG/H.

A powerful reactor-top sludge disposal system for medium-to-large municipal and industrial facilities. Maximum efficiency in a fixed installation.

3.500kg/hour capacity
%75inlet moisture
%1-5outlet moisture
≈0emission
150 kgfuel/hour
Capacity range: 2,975 – 4,025 kg/h

Technical Data

Technical Specifications

Processing Capacity
3,500 kg / Hour (±15%)
Inlet Moisture Content
~%75
Outlet Moisture Content
%1 – %5
Fuel Consumption
150 kg/hour (6,000 kcal coal)
Design
Integrated Reactor-Top System
Volume Reduction
> %90
Environmental Compatibility
EU Standards, SKHKKY
Energy Model
Autocritical — runs on its own biofuel
Hourly Fuel Cost
₺480
150 kg coal × ₺3,200/ton
Disposal Cost per Ton
₺137
Including fuel cost, ton/wet sludge
Coal Price (reference)
$80
6,000 kcal/kg · USD/TRY: ~40 (Sep.2024 reference)

Featured Features

Power and Compactness Together

💪

High Processing Capacity

With a capacity of 3,500 kg/hour, 84 tons of wet sludge are processed per day.

🏗️

Reactor-Top Integration

Installed on top of the existing reactor — no additional structure construction required.

🔄

Autocritical System

Operates with the biofuel it produces. Energy expense is fixed and predictable.

🌿

EU-Compliant Emissions

All emission values are well below legal limits.

📈

Fast Payback

Short payback period thanks to zero shipping cost and ash revenue.

🛡️

Patented Technology

Legal and technical assurance with Stinga technology registered in 134 countries.

Media Gallery

Photo & Video

LET'S FIND THE RIGHT SOLUTION FOR YOUR PLANT TOGETHER

We prepare a free feasibility analysis based on your daily sludge production amount.

Stinga Ø2600 — Reactor-Top Drying System

MEDIUM SCALE.MAXIMUM IMPACT. 2,000 KG/HOUR.

A reactor-top drying system that offers balanced power and cost advantages for medium-sized municipal and industrial treatment plants.

2.000kg/hour capacity
%75inlet moisture
%1-5outlet moisture
≈0emission
80 kgfuel/hour
Capacity range: 1,700 – 2,300 kg/h

Technical Data

Technical Specifications

Processing Capacity
2,000 kg / Hour (±15%)
Inlet Moisture Content
~%75
Outlet Moisture Content
%1 – %5
Fuel Consumption
80 kg/hour (6,000 kcal coal)
Design
Integrated Reactor-Top System
Volume Reduction
> %90
Environmental Compatibility
EU Standards, SKHKKY
Energy Model
Autocritical — runs on its own biofuel
Hourly Fuel Cost
₺256
80 kg coal × ₺3,200/ton
Disposal Cost per Ton
₺128
Including fuel cost, ton/wet sludge
Coal Price (reference)
$80
6,000 kcal/kg · USD/TRY: ~40 (Sep.2024 reference)

Featured Features

Balanced Power, Efficient Cost

⚖️

Optimum Capacity

2,000 kg/hour and 48 tons per day — ideal balance for medium-sized facilities.

💡

Fuel Efficiency

With fuel consumption of 80 kg/hour, the most competitive disposal cost per ton.

🏗️

Easy Integration

Mounted on the existing reactor top — no additional structural cost.

🔄

Autocritical Energy

Operates with its own biofuel; energy costs are predictable and fixed.

📈

Fast ROI

Fast payback through shipping savings + energy independence.

🌿

Environmental Compliance

Operation compliant with EU emission standards and the Kyoto Protocol.

Media Gallery

Photo & Video

LET US INTRODUCE YOUR PLANT TO THIS SYSTEM

We prepare a free feasibility analysis for integration into your existing treatment plant.

Stinga Ø1500 — Reactor-Top Drying System

FOR SMALL AREA.BIG SOLUTION. 500 KG/H.

A compact, entry-level reactor-top sludge drying system for small and medium-sized treatment plants. Low investment, fast payback.

500kg/hour capacity
%75inlet moisture
%1-5outlet moisture
17 kWmotor power
15 kgfuel/hour
Capacity range: 425 – 575 kg/h

Technical Data

Technical Specifications

Processing Capacity
500 kg / Hour (±15%)
Inlet Moisture Content
~%75
Outlet Moisture Content
%1 – %5
Fuel Consumption
15 kg/hour (6,000 kcal coal)
Motor Power
17 kW (installed) / 6.8 kW (used)
Electricity Cost/Hour
₺13,60 (6,8 kW × ~₺2,23/kWh)
Volume Reduction
> %90
Energy Model
Autocritical — runs on its own biofuel
Hourly Fuel Cost
₺48,00
15 kg coal × ₺3,200/ton
Disposal Cost per Ton
₺123
Including fuel + electricity, ton/wet sludge
Hourly Electricity
₺13,60
6.8 kW usage · USD/TRY: ~40 (Sep.2024 reference)

Featured Features

Small Scale, High Efficiency

📦

Compact Design

Easily integrated into small facilities with minimum space requirements.

💰

Low Initial Cost

The most economical member of the Stinga product family — fast and low-risk investment.

⚡

Low Electricity Consumption

Highly economical operation with only 6.8 kW of power consumption.

🔄

Autocritical System

Provides energy independence with the biofuel it produces.

📈

Scalable

Opportunity to transition to a higher model or expand the system in the future.

🌿

Environmentally Compliant

EU emission standards are met — full protection from legal risks.

Media Gallery

Photo & Video

BIG SOLUTION FOR SMALL FACILITIES

Let's determine the most suitable system together based on your facility's daily sludge needs.

Stinga — Poultry House Heating System

WASTE HEAT.ZERO COST. MAXIMUM EFFICIENCY.

Waste heat from the Stinga reactor is directed directly to the poultry house. The 18–33 °C temperature range required for broiler houses is provided without any additional fuel consumption; heating cost drops to zero.

33°Cchick starter temperature
18°Cadult house min.
₺0additional heating cost
%80savings versus traditional
Waste Heatreactor output energy
Operates integrated with all Stinga reactor models — scalable

Technical Data

Technical Specifications

Heat Source
Stinga Reactor Waste Heat — Free
Poultry House Target Temperature
33 °C (week 1 chick) → 18 °C (adult)
Heat Transfer Method
Hot air duct / pipe network — homogeneous distribution
Additional Fuel Consumption
0 kg/h — the reactor is already running
Automation
Thermostat-controlled — automatic adjustment according to target temperature
Moisture Control
Dry hot air reduces poultry litter moisture — prevents ammonia formation
Environmental Compatibility
No fossil fuel is burned — additional emissions are near zero
Integration
Compatible with all Stinga reactor models
Conventional Heating (LPG/Coal)
₺2.800+
1,000 m² poultry house / monthly average
With Stinga Waste Heat
₺0
The reactor is already running — no additional cost
Annual Savings (1,000 m²)
₺33.600+
Estimated savings compared to the conventional system

Featured Features

Why Should You Heat the Poultry House with Stinga Waste Heat?

🔥

Zero Additional Energy Cost

The reactor already operates for sludge/litter disposal. The resulting heat is directed to the poultry house — no extra fuel is needed.

🐔

Ideal Temperature for Broilers

In the 1st week for chicks, 33 °C, and in the adult stage, 18–21 °C optimum growth temperature is uniformly provided.

💧

Litter Dryness

Dry hot air balances indoor poultry house humidity; the litter does not remain wet. Ammonia formation and disease risk decrease.

🌿

Zero Additional Emissions

No additional LPG, natural gas, or coal is burned to heat the poultry house. No carbon footprint is created.

📈

Production Efficiency Increases

In a stable temperature environment, poultry spends energy on growth rather than heating; feed conversion ratio improves.

🔗

Compatible with All Stinga Reactors

From Ø1500 to the Double-Deck system, every model supports this integration.

Media Gallery

Photo & Video

LET'S REDUCE YOUR HEATING BILL TO ZERO

We prepare a free feasibility analysis for poultry house heating integration into your existing or planned Stinga system.

Stinga — Poultry Litter Disposal System

LITTER IS NOT A PROBLEM.TURN IT INTO PROFIT. 1,000 KG/H.

The sawdust + manure mixed poultry litter is dried in the Stinga reactor and its volume is reduced by 90%+. Bad odor, ammonia, and pathogen problems are completely eliminated; the output is sold as organic fertilizer feedstock.

1.000kg/hour capacity
%55inlet moisture content
%10outlet moisture content
>%90volume reduction
30 kgfuel/hour
Capacity range: 850 – 1,150 kg/h

Technical Data

Technical Specifications

Processing Capacity
1,000 kg / Hour (±15%)
Feed Material
Sawdust + manure mixture poultry litter
Inlet Moisture Content
~55% (sawdust + manure mixture)
Outlet Moisture Content
10% – 15% (dry, sterile)
Fuel Consumption
30 kg/h (6,000 kcal coal) — decreases in the autocatalytic cycle
Output Product
Organic fertilizer raw material / sterile ash — marketable
Hygiene
Salmonella, E. coli, pathogens — undetectable after processing
Volume Reduction
> %90
Odor / Emissions
Multi-stage filter — ammonia and bad odor are eliminated
Energy Model
Autocritical — runs on its own biofuel
Environmental Compatibility
EU Standards, SKHKKY, Livestock Waste Regulation
Hourly Fuel Cost
₺107
30 kg coal × ₺3,574/ton
Disposal Cost per Ton
₺107
Including fuel, ton/wet litter
Coal Price (reference)
$80
6,000 kcal/kg · USD/TRY: 44,67

Featured Features

Stinga Difference in Litter Disposal

🦠

Pathogen-Free Output

High-temperature processing completely eliminates Salmonella, E. coli, and other pathogens.

💰

Output Turns Into Revenue

Sterile dry litter can be sold as fertilizer raw material; disposal cost turns into revenue.

👃

Odor Free

Ammonia and bad odor are completely eliminated with the multi-stage filter and high-temperature processing.

🔄

Autocritical System

The organic content of the litter is partially used as fuel; external energy dependence remains minimal.

📊

90%+ Volume Reduction

The volume of heavy wet litter mass is reduced by 90%; storage and transport costs decrease.

🛡️

Regulatory Compliance Assurance

Full compliance with the Livestock Waste Management Regulation and EU norms — zero penalty risk.

Comparison

Traditional Methods vs. Stinga

Criterion
Conventional
Stinga Reactor
Pathogen Risk
High — Salmonella, E. coli
Zero — high-heat sterilization
Odor / Ammonia
Intense — risk of environmental complaints
Zero — multi-stage filter
Volume
Unchanged — high transportation cost
>90% Reduction
Legal Risk
High risk of regulatory noncompliance
Fully Compliant
Output Value
Cost Burden
Marketable organic fertilizer

Media Gallery

Photo & Video

TURN YOUR LITTER FROM A PROBLEM INTO A GAIN

We prepare a free feasibility report based on your farm's daily litter production amount.

Based on TÜİK 2024 Data — Calculated by Population

Daily Sewage Sludge Requirement in Türkiye

Estimated daily wet sludge generation by province (50 g/day dry matter per person, 20% dry ratio → 250 g/day wet per person) and the recommended Stinga system. Sources: TÜİK Address Based Population Registration System 2024, TÜİK Waste Statistics 2024.

* Calculation: Municipal population × 0.25 kg/day → Daily wet sludge (ton). Actual values may vary by ±30% depending on plant type and population. Capacity recommendations are calculated on the basis of 24-hour operation.

# PROVINCE / INSTITUTION POPULATION (2024) DAILY WET SLUDGE (ton) 24H CAPACITY (kg/h) RECOMMENDED SYSTEM

Total 0 province/municipality is shown. The system recommendation has been determined based on the nearest higher capacity.

Audio Reading
0:00 --:--
Speed:
01 / 01
⬇
AI
Our Services
Industrial Machine
Activated Carbon
Mining
Coal Drying
Wood Chips Drying
Bentonite Drying
Sewage Sludge Disposal
Poultry
Residential Heating