Stinga — Double-Deck Drying System
HIGHEST CAPACITY10,000 KG / HOUR
A flagship drying system designed for large-scale municipal treatment plants, delivering maximum efficiency with a double-deck architecture.
Technical Data
Technical Specifications
Featured Features
Why Double-Deck?
Double Efficiency, Same Area
The double-deck architecture offers twice the capacity compared to single-deck systems in the same facility area.
For Large Municipal Facilities
It meets the daily tonnage sludge needs of ASKİ, İSKİ, and large industrial zones with a single system.
Autocritical Energy Cycle
The produced biofuel powers the system; dependence on external energy ends after the first ignition.
Near-Zero Emissions
Operates far below EU emission limits with multi-stage filtration.
90%+ Volume Reduction
The volume of heavy wet sludge is reduced by over 90%, and the ash is compact and stable.
134 Country Patent
Stinga technology is registered in 134 countries — industrial assurance and legal durability.
Based on TÜİK 2024 Data — Calculated by Population
Daily Sewage Sludge Requirement in Türkiye
Daily wet sludge production estimate by province and the recommended Stinga system.
* Calculation: Municipal population × 0.25 kg/day → Daily wet sludge (tons). Actual values may vary by ±30% depending on plant type and population.
| # | PROVINCE | INSTITUTION | POPULATION (2024) | DAILY WET SLUDGE (ton) | 24H CAPACITY (kg/h) | RECOMMENDED SYSTEM | PIECE |
|---|
Total 0 province/municipality shown.
Media Gallery
Photo & Video
The Same Machine — Different Capacity for Coal
with Double-Deck Coal Drying
The Double-deck system can also be used for coal drying. Due to material differences, capacity and moisture levels vary — technical data specific to coal is provided below.
±15% capacity tolerance
In sludge application: 10.000 kg/hour · In coal application: 30.000 kg/hour
Any Coal Type
Lignite, hard coal, bituminous shale — operates regardless of material type.
Double Capacity
With 30.000 kg/hour, dries 720 tons of coal per day — the highest efficiency on site.
₺29/ton Fuel Cost
The lowest ton-based cost in coal drying across the Stinga family.
70 kW Motor Power
Powerful motor suitable for high capacity — uninterrupted 24-hour operation.
Autocritical Energy
Produces its own energy with 240 kg/hour coal fuel, no external dependence.
134 Country Patent
Patented technology compliant with the Kyoto Protocol and meeting EU standards.
LET'S CALCULATE THE MAXIMUM CAPACITY FOR YOU
We prepare a custom feasibility report based on your facility's daily sludge production amount.
Stinga Ø3400 — Single-Deck Drying System
SINGLE-DECK SYSTEM.5,000 KG/HOUR.
A high-capacity single-deck sludge disposal system in which the reactor and rotary kiln operate as a single system.
Technical Data
Technical Specifications
Featured Features
The Power of the Single-Deck System
Single System
The reactor and rotary kiln operate as a single system.
Rapid Commissioning
It is installed on-site and starts operation with minimum preparation time.
Investment Optimization
One system for multiple facilities — spreads capital cost.
Autocritical Energy
Operates with the biofuel it produces, with no external dependency.
High Capacity
With 5,000 kg/h, it meets the needs of large and medium-sized facilities.
Environmentally Friendly
Advanced filter system that meets EU emission standards.
Based on TÜİK 2024 Data — Calculated by Population
Daily Sewage Sludge Requirement in Türkiye
Daily wet sludge production estimate by province and the recommended Stinga system.
* Calculation: Municipal population × 0.25 kg/day → Daily wet sludge (tons). Actual values may vary by ±30% depending on plant type and population.
| # | PROVINCE | INSTITUTION | POPULATION (2024) | DAILY WET SLUDGE (ton) | 24H CAPACITY (kg/h) | RECOMMENDED SYSTEM | PIECE |
|---|
Total 0 province/municipality shown.
Media Gallery
Photo & Video
The Same Machine — Different Capacity for Coal
with Ø3400 Single-Deck Coal Drying
The Single-deck system can also be used for coal drying. Due to material differences, capacity and moisture levels vary — technical data specific to coal is provided below.
±15% capacity tolerance
In sludge application: 5.000 kg/hour · In coal application: 15.000 kg/hour
Any Coal Type
Lignite, hard coal, bituminous shale — operates regardless of material type.
Single-Deck Flexibility
Sewage sludge, coal and biomass operate with the same system.
Calorific Value Increase
Coal reduced from 50%–60% moisture to 1%–5% sees its calorific value increase directly.
35 kW Motor
High-efficiency operation of 15,000 kg/hour with low power consumption.
Autocritical Energy
Produces its own energy with 174 kg/hour coal fuel, no external dependence.
Near-Zero Emissions
Multi-stage filtration system that meets EU and SKHKKY standards.
PLAN THE SINGLE-DECK SYSTEM YOUR WAY
Determine how many facilities you will serve and how often — let us prepare a custom usage plan for you.
Stinga Ø3400 — Reactor-Top Drying System
HIGH CAPACITY.COMPACT STRUCTURE. 3,500 KG/H.
A powerful reactor-top sludge disposal system for medium-to-large-scale municipal and industrial facilities.
Technical Data
Technical Specifications
Featured Features
Power and Compactness Together
High Processing Capacity
With a capacity of 3,500 kg/hour, 84 tons of wet sludge are processed per day.
Reactor-Top Integration
Installed on top of the existing reactor — no additional structure construction required.
Autocritical System
Runs on the biofuel it produces.
EU-Compliant Emissions
All emission values are well below legal limits.
Fast Payback
Short payback period thanks to zero shipping cost and ash revenue.
Patented Technology
Legal and technical assurance with Stinga technology registered in 134 countries.
TÜİK 2024-Based Data
Daily Sewage Sludge Requirement in Türkiye
| # | PROVINCE | INSTITUTION | POPULATION (2024) | DAILY WET SLUDGE (ton) | 24H CAPACITY (kg/h) | RECOMMENDED SYSTEM | PIECE |
|---|
Total 0 province/municipality shown.
Media Gallery
Photo & Video
LET'S FIND THE RIGHT SOLUTION FOR YOUR PLANT TOGETHER
We prepare a free feasibility analysis based on your daily sludge production amount.
Stinga Ø2600 — Reactor-Top Drying System
MEDIUM SCALE.MAXIMUM IMPACT. 2,000 KG/HOUR.
A reactor-top drying system that offers balanced power and cost advantages for medium-sized municipal and industrial treatment plants.
Technical Data
Technical Specifications
Featured Features
Balanced Power, Efficient Cost
Optimum Capacity
2,000 kg/hour and 48 tons per day — ideal balance for medium-sized facilities.
Fuel Efficiency
With fuel consumption of 80 kg/hour, the most competitive disposal cost per ton.
Easy Integration
Mounted on the existing reactor top — no additional structural cost.
Autocritical Energy
Runs on its own biofuel.
Fast ROI
Fast payback through shipping savings + energy independence.
Environmental Compliance
Operation compliant with EU emission standards and the Kyoto Protocol.
TÜİK 2024-Based Data
Daily Sewage Sludge Requirement in Türkiye
| # | PROVINCE | INSTITUTION | POPULATION (2024) | DAILY WET SLUDGE (ton) | 24H CAPACITY (kg/h) | RECOMMENDED SYSTEM | PIECE |
|---|
Total 0 province/municipality shown.
Media Gallery
Photo & Video
LET US INTRODUCE YOUR PLANT TO THIS SYSTEM
We prepare a free feasibility analysis for integration into your existing treatment plant.
Stinga Ø1500 — Reactor-Top Drying System
FOR SMALL AREA.BIG SOLUTION. 500 KG/H.
A compact, entry-level reactor-top sludge drying system for small and medium-sized wastewater treatment plants.
Technical Data
Technical Specifications
Featured Features
Small Scale, High Efficiency
Compact Design
Easily integrated into small facilities with minimum space requirements.
Low Initial Cost
The most economical member of the Stinga product family.
Low Electricity Consumption
Highly economical operation with only 6.8 kW of power consumption.
Autocritical System
Provides energy independence with the biofuel it produces.
Scalable
Opportunity to transition to a higher model in the future.
Environmentally Compliant
EU emission standards are met — full protection from legal risks.
TÜİK 2024-Based Data
Daily Sewage Sludge Requirement in Türkiye
| # | PROVINCE | INSTITUTION | POPULATION (2024) | DAILY WET SLUDGE (ton) | 24H CAPACITY (kg/h) | RECOMMENDED SYSTEM | PIECE |
|---|
Total 0 province/municipality shown.
Media Gallery
Photo & Video
BIG SOLUTION FOR SMALL FACILITIES
Let's determine the most suitable system together based on your facility's daily sludge needs.
Stinga — Poultry House Heating System
WASTE HEAT.ZERO COST. MAXIMUM EFFICIENCY.
Waste heat from the Stinga reactor is directed directly to the poultry house. The 18–33 °C temperature range required for broiler houses is provided without any additional fuel expense.
Technical Data
Technical Specifications
Featured Features
Why Should You Heat the Poultry House with Stinga Waste Heat?
Zero Additional Energy Cost
The reactor is already operating. The heat generated is directed to the house — no extra fuel is required.
Ideal Temperature for Broilers
In the chick's 1st week, 33 °C is provided, and in the adult stage, an optimum temperature of 18–21 °C is provided.
Litter Dryness
Dry hot air balances indoor house humidity; ammonia generation and disease risk decrease.
Zero Additional Emissions
No additional LPG, natural gas or coal is burned to heat the poultry house.
Production Efficiency Increases
At a constant temperature environment, feed conversion rate improves.
Compatible with All Stinga Reactors
From Ø1500 to the Double-Deck system, every model supports this integration.
Media Gallery
Photo & Video
LET'S REDUCE YOUR HEATING BILL TO ZERO
We prepare a free feasibility analysis for poultry house heating integration into your existing or planned Stinga system.
Stinga — Poultry Litter Disposal System
LITTER IS NOT A PROBLEM.TURN INTO GAIN. 500 KG/HOUR.
Wood shavings + manure mixed poultry litter is dried in the Stinga reactor and its volume is reduced by 90%+, gaining value as pellet fertilizer or sterile ash.
Technical Data
Technical Specifications
Featured Features
Stinga Difference in Litter Disposal
Pathogen-Free Output
High-temperature processing completely eliminates Salmonella, E. coli, and other pathogens.
Output Turns Into Revenue
Sterile dry litter can be sold as organic fertilizer raw material.
Odor Free
With multi-stage filtration, ammonia and bad odor are completely eliminated.
Autocritical System
The organic content of the litter is partially used as fuel.
90%+ Volume Reduction
Storage and transport costs decrease.
Regulatory Compliance Assurance
Fully compliant with the Livestock Waste Regulation and EU standards.
Media Gallery
Photo & Video
TURN YOUR LITTER FROM A PROBLEM INTO A GAIN
We prepare a free feasibility report based on your farm's daily litter production amount.
Stinga — Coal Drying Systems
COAL BELOW ITS INHERENT MOISTURESINGLE-DECK DISCHARGING SYSTEM
Reduces coal with 55% moisture to 3%, and we add 50 kcal of value per unit of moisture. Because it is reduced below inherent moisture, moisture does not rise again after rain and snow.
Our Difference from Competitors
Below Inherent Moisture — Permanent Drying
- • Reduces coal to a certain moisture level
- • Stays above inherent moisture
- • Takes on rain/snow in storage or transport
- • Moisture rises again, calorific value decreases
- • Weight increases, transport costs rise
- • Reduces coal below the inherent moisture (3%)
- • Even in rain/snow, moisture does not return
- • Calorific value is preserved during storage and transport
- • Every 1 unit decrease in moisture = +50 kcal/kg
- • From 55% to 3% = a major overall increase in calorific value
System Selection
Which System Should I Choose?
Value Calculation
How Much Does the Value of Your Coal Increase?
The direct impact on your sales price when your 55% moisture coal is dried with Stinga:
Sectors
Coal Drying Application Areas
Coal Mines
On-site drying of wet coal coming from the mine for pre-transport calorific value and weight optimization.
Thermal Power Plants
Drying stock coal to stabilize fuel quality and improve boiler efficiency.
Port & Export
Bringing it to the moisture standard before export — meeting the calorific value requirements of the buyer country.
Coal Stockyards
Preserves long-term calorific value by preventing moisture increase during storage.
Briquetting & Processing
Raw material moisture standardization in briquette production and coal processing plants.
Any Coal Type
Applicable to all coal types — lignite, hard coal, bituminous coal, anthracite.
Media Gallery
Photo & Video
LET'S MAXIMIZE THE VALUE OF YOUR COAL
We prepare a free calorific value increase and revenue analysis based on your daily coal production amount.